In addition to anaerobic digestion taking place in the primary settlement chamber [2] the Ensign:Ultra unit allows the clarified water to pass into a second ‘aeration’ chamber [3] where it is treated to remove the dissolved constituents. Here aerobic bacteria, supported by diffused air and mobile media, ensures full treatment is achieved before the treated effluent and ‘sloughed off’ bacteria flows to a final settlement chamber [10]. The final effluent is then discharged to the drainage field or watercourse via a Polylok filter.
KEY
- Inlet
- Primary settlement chamber
- Aeration chamber
- Compressor with alarm
- Compressor housing (External or internal options)
- RCD / Electrical connection
- PVC pressure pipe for diffuser(s)
- Bio-media
- Stainless steel mesh
10. Final settlement chamber
11. Sludge return
12. Unique Polylok tertiary filter (Ensign:Ultra units)
13. Outlet
14. Access lid
15. Integral lifting eyes
16. Stabilising feet
17. Unique ‘keying-in’ lip

 
    
 Tested and approved to BSEN12566-3/A1:2009 all Ensign units provide treatment well within national consent requirements. Published test results of 11.5:19.2:8.4mg/ltr (BOD:suspended solids:ammonia), with influent concentrations on test higher than those chosen by most competitor plants, effectively equates to 97% pollutant removal.
Tested and approved to BSEN12566-3/A1:2009 all Ensign units provide treatment well within national consent requirements. Published test results of 11.5:19.2:8.4mg/ltr (BOD:suspended solids:ammonia), with influent concentrations on test higher than those chosen by most competitor plants, effectively equates to 97% pollutant removal. 
                                         
                                         
                                        